HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\Client\Settings

Registry values

Value Name

Data Type

Value Data

AssetManagementUseAdditionalFiltering

DWORD

If this value is 1, retired and inactive project copies are hidden in the Manage Tag Links dialog box of the Meridian Asset Management Module.

AutoExpandOnDrag

DWORD

If this value is 1, causes folders to automatically expand when a document is dragged over them.

If this value is 0 (default), the folders do not automatically expand.

BCSiteCacheURL String

URL of the site cache server for use by PowerWeb. This setting overrides the same setting in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client for the current user.

Important!

Users should not work on the same documents from more than one PC with Application Integration in Remote mode and site caches enabled or document content inconsistencies can occur.

BriefCaseCache

DWORD

Location of temporary folder for external format briefcases. If this value is not set (default), uses default temporary directory (%TEMP% environment variable).

BriefCaseOpenFormat

String

Default briefcase metadata format created on 32-bit computers. The default is XML (always on 64-bit computers). Set this value to .mdb to store the metadata in Access format.

ClientServerWebView

DWORD

If this value is 1, the client applications use the AutoVue Client/Server viewer.

If this value is 0, the client applications use the locally installed viewers.

ContextHelpEnabled

DWORD

If this value is 1, enables the context-sensitive Help in client applications.

If this value is 0 (default), context-sensitive Help is cleared.

CopyFiles

DWORD

If this value is 1 (default), enables Duplicator's Copy drawings and presentation documents option. See Duplicate References.

CreateThumbnailOn

DWORD

Sum of bit flags indicating when to update thumbnails.

1 On import

2 On submit working copy

4 On change workflow state

dbgEnableScriptDebugger

DWORD

If this value is 0, do not display the Script Debugger item on the Tools menu of PowerUser.

If this value is 1, show the Script Debugger item if a script debugger is installed.

Configured in the PowerUser Options dialog. See Advanced Options.

DebugMode

DWORD

Sum of bit flags that specify debug levels. For internal use only.

DisableMenuWF

DWORD

If this value is 1, disables the Workflow menu in PowerUser.

If this value is 0 (default), enables the menu.

DisableNotFoundMessage

DWORD

If this value is 1, an information message is not shown when a user attempts to navigate to a document that is outside of the scope of the current navigation view. The view is automatically set to the Explorer view.

If this value is 0 (default), the message is shown and the user must dismiss the dialog box before the view is changed.

DisableOfflineSwitch

DWORD

If this value is 1, disable Offline mode switch in Application Integration.

If this value is 0 (default), do not disable Offline mode. See Disable Offline Mode.

This value overrides the value with the same name in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client.

DisableVaultShortcuts

DWORD

If this value is 0 (default), the Create Shortcut to This Vault command is enabled.

If this value is 1, the command is cleared for the current user.

Note:

This setting must be 0 for the command to be enabled if a scope is active and the command is enabled for that scope.

DisplayManualReferences

DWORD

If this value is 1 (default), enables inclusion of manual references in Assembly structure and Where used dialogs. See Reference Explorer.

DisplayValidationAlerts

DWORD

If this value is 1, show a warning when opening a document in a read-only workflow state.

If this value is 0, do not show a warning.

Configured in the PowerUser Options dialog. See Appearance Options.

DoNotSyncLWS4ShellMenu

DWORD

If this value is 1, the Local Workspace copy of the selected document will not be synchronized before retrieving related shell menu items.

If this value is 0 (default), the document is synchronized.

FlagsFor64bitExtensions

DWORD

Controls the loading of custom extensions by 64-bit client applications.

If this value is 0, do not restrict extension loading.

If this value is 1, do not load extensions.

If this value is 2 (default), load extensions.

GrayTextColor

DWORD

If non-zero, Windows text color is used instead of standard (gray) color for cleared controls. On closing of PowerUser, this value is set back for dimmed controls. Default is 0.

Important!

If this is set to anything but 0x808080, can affect other applications after PowerUser is closed.

HighlightRecentDocs

DWORD

If this value is 1, highlight documents that are less than RecentDocsDateSpan days old.

If this value is 0 (default), do not highlight.

IncludeIntermediate DWORD

If this value is 1 (default), enables the assembly duplicator's Include connecting assemblies option in the Assembly Copy Options dialog box. See Duplicate References.

LastReleasedColor

DWORD

Color to display last released document names in the Show Revisions dialog box.

OfflineMode

DWORD

If this value is 1, use PowerWeb in offline mode.

If this value is 0, do not use offline mode. This can also be set on the Application Integration shortcut menu.

For use with remote access software, set this value to 1 on the remote access client PC and to 0 on the remote access host PC. This value overrides the value with the same name in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client.

QuickSearchAutoAppend

DWORD

If this value is 1 (default), enables the AutoComplete feature in Quick Find combo boxes.

If this value is 0, the feature is cleared.

RebuildDirectoryStructure

DWORD

If this value is 1, sets the assembly duplicator's Folder structure option in the Assembly Copy Options dialog box to Rebuild folder structure relative to each subassembly.

If this value is 0 (default), sets it to Rebuild folder structure relative to the main assembly.

See Duplicate References.

RecentDocsDateSpan

DWORD

Age of documents in days to highlight. If this value is 0 (default), do not highlight.

RedlinesWidth

DWORD

Width in pixels to display Meridian redlines in the Meridian viewer. Configured in the PowerUser Options dialog. See Appearance Options.

ReleaseAllAssembly

DWORD

If this value is 0, release only the documents that are parts of a CAD assembly.

If this value is 1, release the assembly documents and all other documents that are related by Meridian references.

RowsToRetrieveForFind

DWORD

Maximum number of documents to show in Find results at one time.

ShowAllTablesImportDB

DWORD

If this value is 0 (default) the Database Import Wizard in Meridian Enterprise Configurator will only show the tables of the type TABLE (named ranges) that are present in a Microsoft Excel worksheet for selection to import.

If this value is 1, the tables of all types are shown.

ShowRenditions

DWORD

Displays the rendition of the selected document in the viewer pane by default instead of the source file. This setting can also be configured in the PowerUser Options and PowerWeb Preferences dialogs.

For PowerUser, see Appearance Options.

For PowerWeb, see Personal Preferences.

ThumbnailAutoUpdate

DWORD

If this value is 1 (default), enables automatic generation of thumbnails.

If this value is 0, disables automatic generation.

ThumbnailUpdateMode

DWORD

If this value is 1, generates thumbnails with viewer.

If this value is 0 (default), use saved preview images when available.

Configured in the PowerUser Options dialog. See Advanced Options.

UpdateReferences

DWORD

If this value is 1 (default), enables the assembly duplicator's Update SolidWorks references option in the Assembly Copy Options dialog box.

See Duplicate References.

UseImportedFrom

DWORD

This setting overrides the server registry key with the same name described in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Server .

UseWebHelp

DWORD

If this value is 0 (default), local help content is shown when the user presses F1 within a Meridian client application. Learn how to install an updated version of the local help.

If this value is 1, the Meridian online help content is shown.

WebServicesMode

DWORD

If this value is 0 (default), Application Integration operates in Online mode.

If this value is 1, it operates in Remote mode.

This value overrides the value with the same name in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client.

WorkSpaceDB

DWORD

Note:

The following locations will be searched for this value in the order listed and the value of the first location where it is found will be applied:

  1. This registry key (affects only the current user of the PC).

  2. HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client (affects all users of the PC)

Local Workspace database format and version.

Possible values are:

0 – Microsoft Jet database engine (default, installed separately)

1 – SQL Server Compact Edition 3.5 (installed separately)

4 – SQL Server Compact Edition 4 (installed separately)

8 – SQLite (installed only by the Meridian Cloud Client installation package)

Important!

SQL Server Compact is in End of Life status. We provide SQL Server Compact as an option for backwards compatibility only.

WorkSpaceLockID

String

Note:

The following locations will be searched for this value in the order listed and the value of the first location where it is found will be applied:

  1. This registry key (affects only the current user of the PC).

  2. HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client (affects all users of the PC)

A unique value that identifies a user's Local Workspace on each computer that they use. This value is only used by PowerUser. For PowerWeb users, see the WorkspaceLockID value in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\WebLink\Published Locations\<ID>

If a pool of remote access host computers (running PowerUser) will be used, set this to a value to be used by all of the remote access host computers, such as Citrix or RemoteDesktop. The value can be anything so long as it is the same for all of the remote access host computers. For remote access host computers running PowerWeb, see the CommonWorkspace value in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\WebLink\Published Locations\<ID>.

WorkSpaceNoUserName

DWORD

Note:

The following locations will be searched for this value in the order listed and the value of the first location where it is found will be applied:

  1. This registry key (affects only the current user of the PC).

  2. HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Client (affects all users of the PC)

If this value is 1, the user account name is not appended to the Local Workspace folder name.

If this value is 0 (default), the account name will be appended. This is useful only if WorkSpaceLocation is also defined. If set in the HKEY_LOCAL_MACHINE hive on the Meridian web server for the account under which Application Integration runs, Application Integration will periodically clean up the local workspace location of all stale temporary files created for PowerWeb users.

WorkingColor

DWORD

Color to display document names in the view pane for documents under change.

2023