Title block field update upon check-in

When checking in a document with Web Access or in Offline mode that contains synchronized title block properties, the local copy of the document may be different from the version in the vault after the check-in is completed. This happens only when on the Title Blocks tab of the document type, the Read title block fields when a document is checked in through Web Access option is set and one or more of the options under Write title block fields.

The reason this happens is that during the check-in, the title block properties are read from the title block and copied into the vault. After that, the working copy is submitted, which causes the title block fields in the checked-in document to be updated according to the new values. The result is that the document in the vault is newer than the document on the local computer. To resolve this, use the Download Document command in Web Access to download the updated document.