Command-Line Switches

The Windows Installer program's command-line switches can be used together with the Meridian package arguments to further control the installation, such as for display, restart, logging, and repair options. For example, use the /quiet switch to install a product without user interaction. Refer to the Windows Installer help (msiexec /help or /?) for the additional command-line switches supported. For a list of the values supported by the ADDLOCAL property, refer to Install Or Remove Optional Components.

The install options and properties (following /i) must be followed by the display options (/quiet above), restart options (/norestart above), and log options (/log above) for the installation to work.

Example PowerUser installation

The following example uses all of the Meridian options provided in the Windows Installer Packages:

msiexec /i "BlueCielo Meridian Enterprise (x64).msi" LWSFOLDER="C:\BC-WorkSpace\" 
EDMSERVERNAME="Rainier" INSTALLDIR="C:\Program Files\BC-Meridian" WEBACCESSURL=
"http://Rainier/Meridian/Start" ADDLOCAL="Common,AMHook,Download,Viewer,DBX,PUC,Acad2018,
Inventor" TRANSFORMS="1053.mst" /quiet /norestart /log "C:\Temp\BCME2018-Setup.log"

This example will result in the following:

  • The Meridian Enterprise 64-bit clients will be installed

  • The local workspace folder will be set to C:\BC-WorkSpace\

  • The default Meridian application server name will be Rainier

  • The program will be installed in folder C:\Program Files\BC-Meridian

  • The PowerWeb shortcut will be set to http://Rainier/Meridian/Start

  • The program will be installed with the Swedish language

  • The following components will be installed:

    • Common client components

    • PowerUser client

    • Application Integration

    • Viewer

    • Autodesk ObjectDBX viewer support

    • AutoCAD 2018 link

    • Inventor link

  • The installation will run in Quiet mode with no user interaction (including progress bar)

  • The computer will not be restarted upon completion

  • All setup output will be logged to the file C:\Temp\BCME2018-Setup.log

Example PowerWeb installation

The following example uses some of the Meridian options provided in the Windows Installer Packages:

msiexec /i "BlueCielo Meridian Enterprise (x64).msi" LWSFOLDER="C:\BC-WorkSpace\" 
INSTALLDIR="C:\Program Files\BC-Meridian" INSTALLDIR32="C:\Program Files (x86)\BC-Meridian" 
WEBACCESSURL="http://Rainier/Meridian/Start" SCURL="http://SCServer/BCSiteCache" 
ADDLOCAL="Common,AMHook,Download,Viewer,DBX,NETInterops" /quiet /norestart 
/log "C:\Temp\BCME2017-Setup.log"

This example will result in the following:

  • The Meridian PowerWeb client will be installed

  • The local workspace folder will be set to C:\BC-WorkSpace\

  • The 64-bit program files will be installed in folder C:\Program Files\BC-Meridian

  • The 32-bit program files will be installed in folder C:\Program Files (x86)\BC-Meridian

  • The PowerWeb shortcut will be set to http://Rainier/Meridian/Start

  • The site cache URL will be set to http://Rainier/BCSiteCache

  • The following components will be installed:

    • Common client components

    • Application Integration

    • Viewer

    • Autodesk ObjectDBX viewer support

    • .NET interop assemblies

  • The installation will run in Quiet mode with no user interaction (including progress bar)

  • The computer will not be restarted upon completion

  • All setup output will be logged to the file C:\Temp\BCME2018-Setup.log