HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink

Registry values

Value Name

Data Type

Value Data

AcadBaseConfig1

DWORD

Controls the functionality provided by the AutoCAD link:

0 — basic AutoCAD link features only

1 — basic AutoCAD link features plus sheet set support (default)

2 — basic AutoCAD link features plus plain drawing asset management support (not for use with AutoCAD P&ID or AutoCAD Plant 3D)

3 — enable all AutoCAD link features

32 — enable the Synchronize All Data Shortcuts to Vault command in the AutoCAD Civil 3D application link

To learn more about the Synchronize All Data Shortcuts to Vault command, see Data Shortcuts.

AcadPnIDConfig1

DWORD

Controls the P&ID functionality provided by the AutoCAD link. This setting requires AutoCAD P&ID or AutoCAD Plant 3D.

0 — P&ID project features only (default)

1 — P&ID project features plus asset management support

ButtonsForAll

DWORD

If set to 1, shows OK to All and Cancel to All buttons in the confirmation dialog box that appears when a user invokes the Sync Tag Hotspot command on a selection of documents and one or more of the documents has circular references.

By default, the dialog box will appear once for every document in the selection that has circular references so that the user can decide what to do with each document. This setting allows the user to apply their response to all of the problem documents in the selection at one time.

The default is 0, which does not show the batch response buttons.

Civil3DSyncType1,2

DWORD

Controls the synchronization of the folder specified for Civil3DSyncWorkingFolder:

1 — synchronize to the local working folder (on drawing open)

2 — synchronize to the vault (on drawing close)

4 — ask the user before synchronization

8— synchronize only once per AutoCAD session

Civil3DSyncWorkingFolder1,2

DWORD

If this value is 1, synchronizes the entire folder that is specified as the working folder in AutoCAD Civil 3D.

If this value is 0 (default), only the data shortcuts folder is synchronized.

DisableTitleBlockUpdate

DWORD

By default, the AutoCAD link updates mapped title block attributes automatically depending on the settings configured for the vault. This value provides additional control over when title block attribute updates occur.

The possible values are:

0 — perform all automatic updates (default)

1 — disable automatic updates when documents are opened

2 — disable automatic updates when documents are saved

3 — disable all automatic updates

Note:

To control updates to individual title blocks, see the AutoUpdate setting described in Configure Standard Title Block Synchronization.

DocAccessSaveThumbnail

DWORD

Controls the generation of thumbnail images during link updates.

If this value is 0 (default), thumbnails are not saved.

If this value is 1, thumbnails are saved.

Important!

If this value is 1 and thumbnail generation fails for any reason, it could prevent property synchronization, which could be more important.

DocAccessUseTmpFileOnSave

DWORD

This setting is for supporting AutoCAD drawing title block updates over a Citrix remote access connection.

If this setting is 1, the drawing is opened for reading only and changing its content is performed by using a temporary file.

The default is 0.

DocAccessUseTmpFolder

DWORD

This setting is for supporting AutoCAD drawing title block updates over a Citrix remote access connection.

If this setting is 1 and DocAccessUseTmpFileOnSave is set to 1, the temporary file is created in the system temporary folder.

If it is set to 0 (default), the file is created in the same folder as the original file.

ManualUpload DWORD

This setting allows you to opt out of automatic uploads of AutoCAD documents.

0 — setting is disabled.

1 — automatic upload is disabled. A new Upload Document button is added to the Meridian ribbon. This button is visible in remote mode only, and is enabled after the first save of the document.

2 — ignored.

3 — automatic upload is enabled on document close only. A new Upload Document button is added to the Meridian ribbon. This button is visible in remote mode only, and is enabled after the first save of the document.

To learn about remote mode, see Offline Mode And Remote Mode or Application Links In Remote Mode.

RealDwgFonts

String The path to RealDwg fonts installed by the Meridian Enterprise setup program.

RealDwgForceValidity1

DWORD

If this value is 1 (default), the Sync Properties to File command works with AutoCAD Release 14 and older drawings but importing drawings can fail if the title blocks are synchronized also.

If this value is 0, the command does not work with older drawings but importing drawings will not fail if the title blocks are synchronized.

ReleaseNewCivil3DDataShortcuts1,2

DWORD

If this value is 1, Civil 3D data shortcuts are automatically released from their workflows when they are imported to the vault by working folder synchronization.

If this value is 0 (default), the shortcuts are not automatically released.

RepairDocState

DWORD

If this value is 1, it fixes an issue with drawings being read-only and cannot be saved when opened from PowerWeb in Online mode with a site cache configured.

The default value is 0.

SyncTagsOnSave

DWORD If this value is greater than 0, updates Meridian Asset Management Module tag references when drawings are saved.

TurnOnMenuBar

DWORD

If this value is 1, shows the AutoCAD link menu bar.

If this value is 0, the menu bar is hidden.

UseRowRibbon

DWORD

Controls the style of the display of the Accruent page in the AutoCAD Ribbon.

The possible values are:

0 — without items rows

1 — with item rows (default)

For more information, see AutoCAD Link.

Note:
  1. The following locations will be searched for this value in the order listed and the value of the first location where it is found will be applied :
    1. This registry key (affects all users of the PC)
    2. HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink (affects only the current user of the PC)
  2. In addition to the locations listed above, the [Civil_3D] section on the AutoCAD tab of the Application Link Settings in the Environment branch of the vault configuration.