HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\WebLink
Value Name | Data Type | Value Data |
---|---|---|
AhaPortal |
DWORD |
If this value is 1 (default), the item Meridian Wishlist is visible in the user's menu in PowerWeb. If this value is 0, the item is hidden. |
AnonymousUsesNetViewer |
DWORD |
If this value is 0 (default), PowerWeb will not allow anonymous users to use the viewer and thereby claim licenses. If this value is 1, the viewer may be used. |
ApplyMetadata |
DWORD |
If this value is absent or 1, the default behavior occurs. In this case, when users create new documents and set properties that are used in the Field-Path definition, the new values are applied as soon as possible. This can cause new folders to be created with an underscore (_) as the name . If this value is 0, the new values are applied later in the transaction after the folder names have already been set. |
AutoVueServer |
String | URL of the AutoVue rendering server, for example, http://<MyServerName>:5098/servlet/VueServlet. This value is used as the default for new PowerWeb user profiles. |
BCConnector |
String | URL of the Accruent link to the AutoVue rendering server, for example, http://<MyServerName>:8900/wsclient/servlet/DMS. This value is used as the default for new PowerWeb user profiles. |
CADLinkExtensions | String | Semicolon-delimited list of file extensions for which to enable the CAD application links in PowerWeb. The extensions are as follows: dst; dgn; dwg; doc; docx; docm; xls; xlsx; xlsm; ppt; pptx; pptm; vsdx; vsdm. |
CustomFullURL | String |
URL of Meridian PowerWeb for use from outside the LAN (for example, http://<YourDomain>:8082/meridian/start). This setting should only be used as a temporary solution while troubleshooting host name resolution problems with the default URL. Also see UseCurrentHost in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager View Control2\Settings. |
CompanyLogo |
String | The filename of an image to show as the logo in PowerWeb. By default, the Accruent logo is shown. The file must reside in the C:\inetpub\AMM\Img folder on the PowerWeb server. |
DbgXMLPath | String | Path to a folder to save XML files generated by PowerWeb. For debugging only. |
DisableThumbnailUpdate |
DWORD |
Method used to create thumbnail images: 0 (default) — Create the thumbnail image from the preview image stored in the file if it exists. 1 — Do not create thumbnail images at all. 2 — Use the web server to create thumbnail images from the source file only if no preview image exists. 3 — Do not use preview images, create thumbnails using the viewer. This setting is intended for environments in which an AutoVue server deployment will generate thumbnails using the 32-bit Task Server and the UseThumbnailTask setting is 1. |